Access panels and doors for your next project
Shower valves
A shower access panel lets you reach the shower valve and its pipe connections from behind the wall, so a repair doesn't mean breaking tile. Size the opening to the valve body and its connections, not to the trim plate you see on the shower side.
Prices are in Canadian dollars, and delivery after shipping is usually 2–7 business days in Canada (longer to remote areas). Returns go to our Vaughan, Ontario, Canada address.
6 products

Easy-Exs · SAP1414
Rated 4.7 out of 5, 717 ratings online
Fits 10 × 10 to 14 × 14 in openings · Overall 16 × 16 in
CAD $19.99 each

Easy-Exs · PAD1216
Rated 4.4 out of 5, 2,785 ratings online
Maximum service opening 10.35 × 14.35 in (estimated) · Overall 12 × 16 in
CAD $17.99 each

Easy-Exs · PAD1212
Rated 4.4 out of 5, 2,785 ratings online
Maximum service opening 10.35 × 10.35 in (estimated) · Overall 12 × 12 in
CAD $14.99 each

Easy-Exs · SAP0808
Rated 4.7 out of 5, 717 ratings online
Fits 6 × 6 to 8 × 8 in openings · Overall 10 × 10 in
CAD $10.99 each

Easy-Exs · PAD0808
Rated 4.4 out of 5, 2,785 ratings online
Maximum service opening 6.35 × 6.35 in · Overall 8 × 8 in
CAD $9.99 each

Easy-Exs · PAD0606
Rated 4.4 out of 5, 2,785 ratings online
Maximum service opening 4.35 × 4.35 in · Overall 6 × 6 in
CAD $8.99 each
There is no single shower valve size, so measure yours. The opening should expose the valve body and the pipe connections on each side of it, with room to get a wrench on them. In this range, the largest openings come from the SAP1414 panel, which fits square openings from 10 × 10 to 14 × 14 in, and the PAD1216 door.
To find the valve from the back of the wall, measure the handle's height from the floor and its distance from a corner on the shower side, then transfer both to the other side. Make a small exploratory cut there before opening the hole to full size.
Then compare the opening you need with what each model actually gives:
The small round Click-Fit panels aren't listed on this page. Their 4 in and 5.5 in openings are for looking at or reaching a single fitting, and a valve body with its pipes needs more room. The sizes chart has every model if you want to compare.
On many single-handle valves, you can swap the cartridge from the shower side once the handle and trim plate are off. The tile cut under the plate is only as big as the plate hides, though, so it rarely reaches the valve body's connections, the pipe to the shower head, or a leak inside the wall.
That's the work a shower plumbing access panel is for. A bigger trim plate doesn't change it: trim plates come in many shapes and sizes, and they cover the tile cut, not the space behind the wall. If you're replacing the valve itself, plan the back-of-wall opening around the whole valve body and the pipes you'll need to cut and join.
Usually, yes. The panel goes on the dry side of the wall behind the valve, in the bedroom, closet or hallway behind the shower. That keeps it off the tile and out of the spray. It works when the back of that wall is drywall you can cut and reach, without a cabinet or built-in in the way.
The product records make no waterproof or moisture claim for any panel or door here, and none is made to be tiled over or set into a tiled surround. If the only way to the valve is through the tiled side, ask us before ordering rather than fitting a panel into the shower.
If you'll open it once every few years, a removable spring-loaded panel is enough, and the SAP1414 gives the widest opening range here. If the panel sits in a closet or hallway where it may get bumped, or you'd rather the cover stayed with the wall, choose a hinged door with a latch.
The spring-loaded panels carry a large wire-loop spring on the back of the cover, so the whole cover lifts out. The hinged doors have a frame, a hinge and a latch, and the door stays attached when you open it; see all of them on the access doors page. A tub and shower combination may also need access to the drain, which the bathtub access panel page covers.
Measure your valve: the opening should expose the valve body, its pipe connections and room for a wrench. In this range, the SAP1414 fits square openings from 10 × 10 to 14 × 14 in, and the PAD1216 door has a 10.35 × 14.35 in (estimated) service opening.
No. The SAP1414 is sold as 14 × 14 in and fits openings from 10 × 10 to 14 × 14 in, but its overall cover is 16 × 16 in. Leave room on the wall for the full cover.
Usually the back: the dry side of the wall behind the valve, in the room, closet or hallway behind the shower. That keeps the panel off the tile and out of the spray.
None of the panels or doors listed here is made to be tiled over, and the product records make no waterproof or moisture claim. Put the panel on the dry side of the wall, behind the valve.
Not always. On many single-handle valves the cartridge comes out from the shower side once the handle and trim plate are off. A panel matters for work on the valve body, its pipe connections or a leak inside the wall.