Skip to content
Buy Access Panels

Junction and electrical boxes

Electrical access panels for junction boxes

On this page, an electrical access panel means a panel or door in a wall or ceiling that keeps a junction box or electrical box reachable. It is not a breaker panel, load center or breaker panel cover, and we don't sell those. Size the opening to the box and the wiring you need to reach.

Prices are in Canadian dollars, and delivery after shipping is usually 2–7 business days in Canada (longer to remote areas). Returns go to our Vaughan, Ontario, Canada address.

9 products

Products

  • Easy-Exs 8 × 8 in hinged access door, white plastic, open, with a shut-off valve behind the opening

    Easy-Exs · PAD0808

    8x8 in Plastic Drywall Access Panel with Hinged Door

    Rated 4.4 out of 5, 2,785 ratings online

    Maximum service opening 6.35 × 6.35 in · Overall 8 × 8 in

    CAD $9.99 each

    • 10+ panels: $8.99 each
    • 80+ panels: $7.99 each
  • Easy-Exs 12 × 12 in hinged access door, white plastic, open, with a water meter behind the opening

    Easy-Exs · PAD1212

    12x12 in Plastic Drywall Access Panel with Hinged Door

    Rated 4.4 out of 5, 2,785 ratings online

    Maximum service opening 10.35 × 10.35 in (estimated) · Overall 12 × 12 in

    CAD $14.99 each

    • 10+ panels: $12.49 each
    • 80+ panels: $9.99 each
  • EASY-EXS Spring-Loaded Access Panel 8 × 8 in — 10 × 10 in Overall — actual product photograph

    Easy-Exs · SAP0808

    8x8 in Spring-Loaded Plastic Drywall Access Panel

    Rated 4.7 out of 5, 717 ratings online

    Fits 6 × 6 to 8 × 8 in openings · Overall 10 × 10 in

    CAD $10.99 each

    • 10+ panels: $9.49 each
    • 80+ panels: $7.99 each
  • Easy-Exs 6 × 6 in hinged access door, white plastic, open, with a shut-off valve behind the opening

    Easy-Exs · PAD0606

    6x6 in Plastic Drywall Access Panel with Hinged Door

    Rated 4.4 out of 5, 2,785 ratings online

    Maximum service opening 4.35 × 4.35 in · Overall 6 × 6 in

    CAD $8.99 each

    • 10+ panels: $7.99 each
    • 80+ panels: $6.99 each
  • EASY-EXS Spring-Loaded Access Panel 14 × 14 in — 16 × 16 in Overall — actual product photograph

    Easy-Exs · SAP1414

    14x14 in Spring-Loaded Plastic Drywall Access Panel

    Rated 4.7 out of 5, 717 ratings online

    Fits 10 × 10 to 14 × 14 in openings · Overall 16 × 16 in

    CAD $19.99 each

    • 10+ panels: $17.99 each
    • 80+ panels: $15.99 each
  • Easy-Exs 12 × 16 in hinged access door, white plastic, open, with a water meter behind the opening

    Easy-Exs · PAD1216

    12x16 in Plastic Drywall Access Panel with Hinged Door

    Rated 4.4 out of 5, 2,785 ratings online

    Maximum service opening 10.35 × 14.35 in (estimated) · Overall 12 × 16 in

    CAD $17.99 each

    • 10+ panels: $14.99 each
    • 80+ panels: $11.99 each

Is an electrical access panel the same as a breaker panel?

No. A breaker panel (a load center) is the equipment that holds your circuit breakers, and its cover or door belongs to that equipment. The products on this page are plastic access panels and doors set into a wall or ceiling surface, in front of a junction box or other wiring you'll need to reach later.

If you're looking for a replacement door or cover for a breaker panel, this isn't it; ask the panel's manufacturer or an electrician. Everything below is about keeping a box behind drywall within reach.

Does a junction box need an access panel?

An access panel is one way to keep a junction box reachable once it's behind a finished surface. In Canada, the rule comes from your provincial electrical code: ask your electrical inspector what access a box needs and what counts as accessible in your project.

Whatever the panel, keep the box's own cover plate on. The access panel sits in the wall or ceiling surface; it isn't a box cover, and the product records don't list any model as an electrical enclosure.

What size access panel do I need for an electrical box?

Bigger than the box face, with room to take off the box cover and pull the wiring forward. Measure the box and its cover plate, then add hand room on each side. For a single box, start with the PAD0808 door's 6.35 × 6.35 in service opening, if the box fits inside it with room to spare.

Other sizes in the range, by what you need to reach:

  • A single box. The PAD0808 door is 8 × 8 in overall with a 6.35 × 6.35 in service opening. The SAP0808 panel fits openings from 6 × 6 to 8 × 8 in under a 10 × 10 in cover. The PAD0606 door's service opening is only 4.35 × 4.35 in, so check that your box fits through it.
  • Several boxes or splices. The PAD1212 door is 12 × 12 in overall with a 10.35 × 10.35 in (estimated) service opening, and the SAP1414 panel fits square openings from 10 × 10 to 14 × 14 in under a 16 × 16 in cover.
  • A round hole. The round panels fit a 4 in opening (SAP50), a 5.5 in opening (PAP65) or openings from 6 to 9 in across (SAP10R). Use one only if the box will pass through the hole.

The sizes chart lists every opening and cover.

Hinged door or removable panel over a junction box?

A hinged electrical panel access door keeps its cover attached to the frame and closes with a latch, so the cover can't go missing between visits. A removable spring-loaded panel works too, but the whole cover comes off, so it needs somewhere to go while you work.

All four doors, from the PAD0606 to the PAD1216, are framed and close on a latch; compare them on the access doors page. The spring-loaded panels are held by one large wire-loop spring fixed to the cover itself. The Click-Fit round panels, SAP50 and PAP65, use opposing spring clips.

Where should an access panel for a junction box go?

Directly in front of the box, where the drywall around the hole is flat and undamaged on every side and you can reach in with both hands. Check that cabinets, shelving or a door swing won't block it later, and keep the cut clear of other cables and pipes in the same bay.

Turn off the circuit before cutting near wiring, and make a small exploratory cut first to confirm where the box sits. None of these panels or doors is fire-rated, and a general product description does not establish a fire rating, certification or approval for a particular wall or ceiling assembly.

Questions

Is this an electrical panel cover?

No. These are access panels and doors for a wall or ceiling opening in front of a junction box or other wiring. We don't sell breaker panels, load centers or their covers.

Does a junction box have to stay accessible?

In Canada, the rule comes from your provincial electrical code. Ask your electrical inspector what access a junction box needs and what they accept.

What size access panel do I need for a junction box?

Larger than the box and its cover plate, with room for your hands. The PAD0808 door has a 6.35 × 6.35 in service opening and is 8 × 8 in overall; for larger work, the SAP1414 panel fits openings from 10 × 10 to 14 × 14 in.

Are these access panels rated for electrical use?

The product records list no electrical rating for any model, and none is fire-rated. They are plastic access panels and doors, not electrical enclosures, so the box keeps its own cover.

Can I use a round access panel over an electrical box?

Only if the box and the wiring you need will pass through the hole. The round panels fit a 4 in opening (SAP50), a 5.5 in opening (PAP65) or openings from 6 to 9 in (SAP10R). Measure the box before choosing one.