Easy-Exs · PAD0808
8x8 in Plastic Drywall Access Panel with Hinged Door
Rated 4.4 out of 5, 2,789 ratings online
Maximum service opening 6.35 × 6.35 in · Overall 8 × 8 in
USD $9.49 each
- 10+ panels: $8.49 each
- 80+ panels: $7.49 each
Access panels and doors for your next project
Junction and electrical boxes
On this page, an electrical access panel means a panel or door in a wall or ceiling that keeps a junction box or electrical box reachable. It is not a breaker panel, load center or breaker panel cover, and we don't sell those. Size the opening to the box and the wiring you need to reach.
9 products

Easy-Exs · PAD0808
Rated 4.4 out of 5, 2,789 ratings online
Maximum service opening 6.35 × 6.35 in · Overall 8 × 8 in
USD $9.49 each

Easy-Exs · PAD1212
Rated 4.4 out of 5, 2,789 ratings online
Maximum service opening 10.35 × 10.35 in (estimated) · Overall 12 × 12 in
USD $13.99 each

Easy-Exs · SAP0808
Rated 4.6 out of 5, 718 ratings online
Fits 6 × 6 to 8 × 8 in openings · Overall 10 × 10 in
USD $9.49 each

Easy-Exs · PAD0606
Rated 4.4 out of 5, 2,789 ratings online
Maximum service opening 4.35 × 4.35 in · Overall 6 × 6 in
USD $8.49 each

Easy-Exs · SAP1414
Rated 4.6 out of 5, 718 ratings online
Fits 10 × 10 to 14 × 14 in openings · Overall 16 × 16 in
USD $18.49 each

Easy-Exs · PAD1216
Rated 4.4 out of 5, 2,789 ratings online
Maximum service opening 10.35 × 14.35 in (estimated) · Overall 12 × 16 in
USD $16.49 each

Easy-Exs · SAP10R
Rated 4.5 out of 5, 243 ratings online
Fits 6–9 in round openings · Overall 10 in diameter
USD $10.99 each

Easy-Exs · PAP65
Fits 5.25–5.5 in round openings (smallest estimated) · Overall 6.5 in diameter
USD $6.49 each

Easy-Exs · SAP50
Fits 3.75–4 in round openings (smallest estimated) · Overall 5 in diameter
USD $5.49 each
No. A breaker panel (a load center) is the equipment that holds your circuit breakers, and its cover or door belongs to that equipment. The products on this page are plastic access panels and doors set into a wall or ceiling surface, in front of a junction box or other wiring you'll need to reach later.
If you're looking for a replacement door or cover for a breaker panel, this isn't it; ask the panel's manufacturer or an electrician. Everything below is about keeping a box behind drywall within reach.
A junction box needs to stay reachable, and an access panel is one way to do that once it's behind a finished surface. Section E3905.10 of the 2021 International Residential Code, which draws on NEC 314.29, says junction, pull and outlet boxes must be installed so the wiring in them can be accessed without removing any part of the building.
Codes vary, and your local building department or inspector decides what counts as accessible in your project. The IRC and the NEC are US codes; in Canada, ask your local electrical inspection authority which code applies. Whatever the panel, keep the box's own cover plate on. The access panel sits in the wall or ceiling surface; it isn't a box cover, and the product records don't list any model as an electrical enclosure.
Bigger than the box face, with room to take off the box cover and pull the wiring forward. Measure the box and its cover plate, then add hand room on each side. For a single box, start with the PAD0808 door's 6.35 × 6.35 in service opening, if the box fits inside it with room to spare.
Other sizes in the range, by what you need to reach:
The sizes chart lists every opening and cover.
A hinged electrical panel access door keeps its cover attached to the frame and closes with a latch, so the cover can't go missing between visits. A removable spring-loaded panel works too, but the whole cover comes off, so it needs somewhere to go while you work.
All four doors, from the PAD0606 to the PAD1216, are framed and close on a latch; compare them on the access doors page. The spring-loaded panels are held by one large wire-loop spring fixed to the cover itself. The Click-Fit round panels, SAP50 and PAP65, use opposing spring clips.
Directly in front of the box, where the drywall around the hole is flat and undamaged on every side and you can reach in with both hands. Check that cabinets, shelving or a door swing won't block it later, and keep the cut clear of other cables and pipes in the same bay.
Turn off the circuit before cutting near wiring, and make a small exploratory cut first to confirm where the box sits. None of these panels or doors is fire-rated, and a general product description does not establish a fire rating, certification or approval for a particular wall or ceiling assembly.
No. These are access panels and doors for a wall or ceiling opening in front of a junction box or other wiring. We don't sell breaker panels, load centers or their covers.
Section E3905.10 of the 2021 International Residential Code says junction boxes must be installed so the wiring in them can be accessed without removing any part of the building. Codes vary, so ask your local building department or inspector what they accept.
Larger than the box and its cover plate, with room for your hands. The PAD0808 door has a 6.35 × 6.35 in service opening and is 8 × 8 in overall; for larger work, the SAP1414 panel fits openings from 10 × 10 to 14 × 14 in.
The product records list no electrical rating for any model, and none is fire-rated. They are plastic access panels and doors, not electrical enclosures, so the box keeps its own cover.
Only if the box and the wiring you need will pass through the hole. The round panels fit a 4 in opening (SAP50), a 5.5 in opening (PAP65) or openings from 6 to 9 in (SAP10R). Measure the box before choosing one.